<LOGO>
FM Transmitter Measurement Report
Created: 2025-10-22 16-24-58
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.20 MHz 5/5, 61 dBuV YLEX
Pilot RDS Phase Difference
7.2 kHz 2.2 kHz 70 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 63 kHz 19060 1,2802
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
1,0 dBr 3,24 dBr 4,8 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"YLEX " 6202 10 (Pop M) 0 1 1 1 16:24, 22.10.2025
RT
"ADDI "
AF EON
91.5, 91.8, 91.9, 92.6, 93.2, 94.3, 96.1 MHz 6203, 6207, 6205, 6201
FM Scope Max at: 63 kHz MIN: 9 kHz % above 76 kHz: 1,2802 Acquired: 2025/10/22 16.23.55 Total samples: 19060 Equivalent time: 0:15:53 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 4,8 dBr MIN: 1,0 dBr AVE: 3,24 dBr % above 12,2 dBr: 0,0 Last value: 4,3 dBr (2025/10/22 16.23.55) 16.10 16.12 16.14 16.16 16.18 16.20 16.22 0 2 4 Pm [dBr]